无标题文档● 18GHz ~ 22GHz
● WR51,C-type or R type
● Vertical welding pin type
● 28V Common positive or common negative control
Microwave Parameters
驻波比(max) VSWR(max) | 1.15 |
隔离度 dB(min) Isolation(min) | 55 |
插入损耗 dB(max) Insertion Loss(max) | 0.15 |
额定功率 (W) Rated power(W) | 100 |
Appearance and Characteristics
外观 Appearance | 重量(g) mass(g) | ≤ 200 |
机械寿命 mechanical life | ≥ 10 万次 ≥ 100000 times |
表面涂覆 surface coating | 导电氧化或黑色温控漆 Conductive oxidized or black temperature control paint |
电气参数 Electrical parameters | 电流(mA) amps(mA) | ≤ 500 |
脉冲宽度(ms) pulse width(ms) | 600 ~ 1000 |
转换时间(ms) conversion time(ms) | ≤ 600 |
工作电压(V) operating voltage(V) | 最小 minimal value | 额定 rating | 最大 maximum value |
22 | 28 | 35 |
环境特性 Environmental Characterization | 正弦振动 sinusoidal oscillation | 20g |
随机振动 random vibration | 17.7grms |
冲击响应谱 Shock response spectrum | 1600g |
耐辐照 radiation resistance | 25Mrad(Si) |
真空释气 vacuum degassing | TML ≤ 1.0%,CVCM ≤ 0.1% |
电磁泄漏 electromagnetic leakage | ≥ 65dBi |
工作温度 operating temperature | -35℃~ +85℃ |
贮存温度 storage temperature | -40℃~ +90℃ |
Operation requirements
For products with welding pin structure, when welding the welding pin, the welding area should be controlled within 3mm of the top of the lead rod, the welding temperature should be 280±5℃, and the welding time should not be more than 3s each time.
Before using the switch, make sure that the RF connector is clean and free of excess material.
When the microwave switch is switched, the microwave output ports should not have microwave power signals, so as to avoid burning the connected instruments and equipments.
The microwave port not connected to the circuit should be terminated with a matching load or waveguide load with an impedance of 50 ohms.
When energizing the switch, make sure that the positive and negative terminals of the switch are accurately connected to the positive and negative terminals of the power supply.
When the switch is not used for a long period of time, the RF connector should be protected by a protective cap and protective tape should be applied to the ventilation holes.
The connection and unloading of the RF port should be carried out with the help of a force-limiting wrench.
Use the pulse signal in accordance with the detailed specification to energize the coil, and prohibit the use of DC signal to energize the coil for a long period of time, so as to avoid overheating of the coil.
All screws on the product should not be loosened or tightened.
The product should be used in a cleanliness of 100,000 (and above), humidity within the range of 30% - 60% of the environment, please wear a protective cover when operating, and take appropriate measures to prevent static electricity.
Telemetry current ≤ 10mA.